Description:
TH100 temperature and humidity transmitter using semiconductor components sensitive to measure the air temperature, humidity, suitable for indoor environment measurement, sensitive components to be monitored to ambient temperature, humidity, output intelligent digital signal.
The transmitter installed in the most representative of the measured state of the environment to avoid dead ends at the installed in the air flow is impeded.
Product Features:
1) Small size, beautiful appearance;
2) Shell dust-proof design and direction and out of line design;
3) Simplicity: easy to install, easy to use;
4) Intuitive: the LCD display and intuitive information, the keyboard is easy to operate;
5) Scalability: RS485 interface for remote group of network management;
6) Stability: all year round 24 hours of continuous work, no special maintenance.
Main Technical Parameters:
Model: TH100
Rated voltage: DC12V
Measuring range: Temperature: -20 ? ~ 70 ? Humidity: 0 ~ 100% rh
Measurement Accuracy: Temperature: ± 0.5 ° C, humidity: ± 4.5% rh
Output range: The RS485 serial output temperature: -20 ? ~ 70 ? Humidity: 0 ~ 100% rh
RS485 serial output
RS485 Type: Multi-point, duplex (static and dynamic variables)
Connection: 2-wire, the maximum communication distance of 1200m, the terminal directly connected
Address :1-255, via the button to select
Protocol: MODBUS
Data format: 1 start bit, 8 data bits, no parity, 1 stop bit
Baud Rate: 1200 bit / s, 2400 bit / s, and 4800 bit / s, and 9600 bit / s, and 19200 bit / s, and 38.4 thousand-bit / s, and 57.6 thousand bit / s, and 115.2 thousand bit / s
Electrical isolation: The communication port: Voltage AC500V, 1mA, 1 minute
Communication port between the main circuit: Voltage AC500V, 1mA, 1 minute
EMC indicators: To meet the European standard: EN 55 022 CLASS B, EN 55024, CISPR 22 CLASS B, CISPR 24
IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Meet the national standard: GB 9254 CLASS B, GB / T 17618
GB 17625.1,IEC 17625.2, GB / T 17626.2, GB / T 17626.3, GB / T 17626.4, GB / T 17626.5,
GB / T 17626.6, GB / T 17626.8, GB / T-17626.11
Effective working area of 10-20m2 / only
Installation: Indoor wall mounting, ceiling, ceiling installation
Quality: Subject: about 200g, base: about 50g
User Manual: